High performance photonics. Made in Switzerland.

background

ORIGAMI - Low-noise femtosecond laser modules

The ORIGAMI low-noise femtosecond laser family is designed for maintenance free 24/7 operation over the entire temperature range and product lifetime.

The ORIGAMI guarantees sustained performance between 10 °C - 40 °C ambient temperature without intermittent pulse drop-outs, interruption of mode-locking or start-up difficulties at different ambient temperatures.

The ORIGAMI generates pedestal-free, transform limited pulses with unmatched temporal and spectral purity and stability, free of ASE background noise.

Origami

ORIGAMI Model

-15

-10

-8

Center wavelength, nm

1530 - 1570

1025 - 1070

765 - 785

Pulse duration sech2  , fs

< 170 - 600

< 150 - 500

< 150 - 500

Average output power, mW

> 100

> 150

> 30

Optical isolation

> 40 dB

-

> 40 dB

Pulse repetition rate, MHz

40, 75, 76, 80, 100

Spectral Bandwidth

transform limited (Δτ *Δλ ~ 0.32)

Output polarization

linear, polarization extinction ratio > 23 dB

Output beam

fiber output / free space

Beam quality factor M2      

< 1.1

Amplitude noise

< 0.1% rms (1 h)

Warm-up time

< 10 minutes

Operation temperature

10 °C - 40 °C

Storage temperature

-15 °C - 65 °C

Size laserhead

296 x 112 x 54 mm3

Power supply

90 - 264 VAC, 47 - 63 Hz

Features:


- Push-button operation, maximum useability: No PC required, no hidden reset or adjustment knobs or screws, guaranteed maintenance free 24/7 operation.


- It runs with a 5V/24V laptop-like power supply, laser and driver are passively air cooled, no chiller, no forced air cooling or long warm up times.


- Very high quality spectral and temporal pulse shape: No pedestal or satellite pulses, clean optical spectrum with highly constant and repeatable center wavelength, bandwidth and spectral shape.


- ORIGAMI -8 comes with dual wavelength output 15xx nm / 7xx nm (option)


- Record-low amplitude (RIN) and phase noise (timing jitter),
no ASE background noise (no optical amplifier built-in).


• RMS amplitude noise < 0.1 % over 1 h
• RMS timing jitter < 100 fs [100 Hz - 1 MHz] (free running)
• RMS timing jitter < 35 fs [10 Hz - 1 MHz] (requires synchronization option)
• Pulse repetition rate frequency drift < 10 Hz over 1h (free running)


Please inquire for other wavelengths, pulse repetition rates or pulse durations.

 

background
background

Options

  • Synchronization to external clock
  • Repetition rate tunability
  • Simple electronic interface for pump power control
  • Ask for SHG and THG
  • See our Accessories Page

Applications

  • Supercontinuum generation
  • Optical coherence tomography
  • Frequency metrology
  • THz generation
  • Homeland security
  • Multi-photon microscopy
  • Sensing, Lidar
  • Spectroscopy
  • R&D